DO Supply, Inc. sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with DO Supply, Inc. and not the manufacturer. DO Supply, Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products. Read more
DO Supply, Inc. sells surplus and refurbished products which are sourced through independent channels. All warranties and support, if applicable, are with DO Supply, Inc. and not the manufacturer. DO Supply, Inc. is not an authorized distributor or representative for the listed manufacturers and makes no representations as to any quality control performed by any listed manufacturer on the products.
Some of the products sold by DO Supply, Inc. may come with firmware installed on them. DO Supply, Inc. makes no representation as to your ability or right to download, obtain, or use any firmware provided by the product's manufacturer. To the extent you wish to use such firmware, it is your responsibility to comply with the terms of any applicable license or other such agreement related to the download, installation, or use of the firmware. DO Supply, Inc. makes no representation that the version of the firmware that is installed on any product it sells is appropriate for your needs or use. Further, DO Supply, Inc. does not sell, re-sell, or license software that may be needed to operate certain hardware and customers must obtain any necessary software licensing, maintenance, or upgrades from the manufacturer or other authorized source. To the extent any of the products sold by DO Supply, Inc. requires software for operation, you acknowledge that DO Supply, Inc. does not sell or license such software and that it is solely your responsibility to obtain the software or a proper license to use it from authorized sources. Read less
MPN | HLD3600T106W |
Product Line | Series C L Frame |
Manufacturer | Eaton Cutler-Hammer |
This is a Allen Bradley/Rockwell Automation Variable Frequency AC Drive. The amperage rating of this unit is 600 amps.
travel_explore
We offer international delivery through FedEx, UPS, and DHL.
security
We are proud to offer a one-year DO Supply Warranty with all purchases.
payment
We are happy to accept payment through all major credit card providers.
Amps | 600 Amps |
Dimensions (W x H x D) | 8.25 x 10.75 x 4.06 inches |
Frame | L |
Interrupting Capacity | 100 kAIC at 240 Volts AC |
Part Number/Catalog No. | HLD3600T106W |
Poles | 3 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Unit Type | OPTIM |
Weight | 20 pounds |
The Eaton Cutler-Hammer HLD3600T106W is an HLD type of electronic molded case circuit breaker housed in an L frame. The device supports automating trip activity when it detects a ground fault or an overcurrent condition. The trip will happen as the result of a shunt or an undervoltage condition too. This MCCB features the toggle handle operating mechanism. The handle is automatically moved to the middle (trip) position and it serves as a switching position indicator. The handle can be moved from this position manually to off or the on positions. The electronic trip unit installed in this module is the OPTIM 1050 that performs the LSIG type of trip. This means that the HLD3600T106W has adjustable long delay protection, short delay protection, instantaneous protection, and ground fault protection settings.
In the open air at 40 degrees Celsius (104 degrees Fahrenheit), the HLD3600T106W MCCB can operate continuously at up to 600 Amps. It will conduct this amount of current without exceeding a 50 degrees Celsius maximum temperature at the line and input terminals. Its OPTIM 1050 trip unit encompasses thermal temperature-protective mechanisms that start a trip operation as a self-protection feature if the internal ambient temperature reaches approximately 90 degrees Celsius (184 degrees Fahrenheit). In the case of overheating, a thermal memory effect will prevent this item from being reenergized immediately. The users must wait approximately 5 minutes for the cabling’s internal temperature to cool down enough to be touched and repaired. This is a 3-phase protective HLD3600T106W that has 100 kAIC of interrupting capacity at 240 Volts AC and 65 kAIC of interrupting capacity at 480 Volts AC.
Manufacturer Part Numbers (MPNs) are often difficult to read. Here are some commonly mistaken versions for the HLD3600T106W: